Tab Size(mm) |
Applicable wire size |
Contact resistance |
Leak current |
Insulation resistance |
Seal |
Materials |
|
0.13〜0.5㎣ |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
0.3〜0.5㎣ |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
0.3〜2.0㎣ |
- Initial
- 3mΩMax.
- after durability tests
- 10mΩMax.
|
100μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
0.3〜3.0㎣ |
- Initial
- 3mΩMax.
- after durability tests
- 10mΩMax.
|
100μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
0.5〜8.0㎣ |
- Initial
- 3mΩMax.
- after durability tests
- 10mΩMax.
|
100μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 8mΩMax.
- after durability tests
- 16mΩMax.
|
50μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 3mΩMax.
- after durability tests
- 10mΩMax.
|
100μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal
- Silicone
|
|
— |
- Initial
- 3mΩMax.
- after durability tests
- 10mΩMax.
|
100μAMax. |
100MΩMin. |
- Initial
- 50kPaMin.
- after durability tests
- 30kPaMin.
|
- Housing
- PBT, PA6T
- Terminal
- Brass, Heat-Resistant Copper Alloy
- Wire Seal